Copper core PVC insulated PVC sheathed steel strip armored control cable KVV22

Detail

Product name: Control cable

Products are suitable for metallurgy, electric power, petrochemical industry and other industrial and mining enterprises in the ac rated voltage (U / U0) 450 / 750V and below electrical instruments, distribution device signal transmission, control and measurement system, protection line and other occasions to use the number of core, can shorten the line laying time, model specifications, according to the need to meet the shielding, armor, flame retardant, fire resistance and other performance requirements....


Implementation standard: GB / T 9330-2008, enterprise standards

Product introduction: the product is suitable for control, monitoring circuit and protection line occasions. PVC The long-term allowable operating temperature of insulated cables is not more than 70℃, and the long-term operating temperature of XLPE insulated cables is not more than 90℃.(Note: The above model cables have low smoke halogen free, flame retardant and fire resistant structures.)

1、The low smoke and low halogen flame retardant control cables are manufactured according to the enterprise standards, and the flame retardant characteristics meet the requirements of GB / T18380.3, GB / T17651 and GB / T17650.

2、2. The low-smoke halogen-free flame retardant control cable is manufactured according to the enterprise standard, and the flame retardant characteristics meet the requirements of GB / T18380.3, GB / T17651 and GB / T17650.

3、3. The flame retardant control cable is manufactured according to the enterprise standard, and the flame retardant characteristics meet the provisions of GB / T18380.3.


Model number, name, and scope of use

model

name

Main scope of use

KVV

PVC-insulated and PVC-sheathed control cable

Laying in indoor, cable trench, pipeline and other fixed occasions

KVVP

PVC-insulated PVC-sheathed braided shielded control cable

Laying in indoor, cable trench, pipeline and other fixed places requiring shielding

KVVP2

PVC insulated PVC sheath copper strip shielded control cable

Laying in indoor, cable trench, pipeline and other fixed places requiring shielding

KVVP3

PVC insulated PVC sheathed aluminum-plastic composite strip shielding control cable

Laying in indoor, cable trench, pipeline and other fixed places requiring shielding

KVV22

PVC-insulated and PVC-sheathed steel strip armored control cable

Laying in the indoor, cable trench, pipeline and other fixed occasions to withstand a large mechanical external force

KVVP2-22

PVC insulated PVC sheath copper strip shielded steel strip armored control cable

Laying in indoor, cable trench, pipeline and other required shielding, withstand large mechanical external force fixed occasions

KVV32

PVC-insulated and PVC-sheathed fine steel wire armored control cable

Laying in indoor, cable trench, pipeline and other bear large mechanical external force, large span fixed occasions

KVVR

PVC insulated PVC sheath control flexible cable

Laying in the indoor movement requires soft and other occasions

KVVRP

PVC-insulated PVC-sheathed braided shielding control flexible cable

Laying in the indoor movement requirements of soft, shielding and other occasions



name

operative norm

model

the classification of voltage

specifications

PVC insulated PVC sheath (or flame retardant, or refractory) control cable with rated voltage of 450 / 750V and below

GB/T19666-2005

GB/T9330.2-2008

(Z*-)、(Z*N-)KVV、(Z*-)、(Z*N-)KVVP

450/750V

2*0.75~61*0.75、2*1.0~61*1.0、2*1.5~61*1.5、

2*2.5~61*2.5、2*4~14*4、2*6~14*6、2*10~10*10

(Z*-)、(Z*N-)KVVP2、(Z*-)、(Z*N-)KVVP 3

4*0.75~61*0.75、4*1.0~61*1.0、4*1.5~61*1.5、4*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10

(Z*-)、(Z*N-)KVV22、(Z*-)、(Z*N-)KVVP2-22

7*0.75~61*0.75、7*1.0~61*1.0、4*1.5~61*1.5、4*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10

(Z*-)、(Z*N-)KVV32

19*0.75~61*0.75、19*1.0~61*1.0、7*1.5~61*1.5、7*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10

(Z*-)、(Z*N-)KVVR

2*0.5~61*0.5、2*0.75~61*0.75、2*1.0~61*1.0、2*1.5~61*1.5、2*2.5~61*2.5

(Z*-)、(Z*N-)KVVRP

2*0.5~61*0.5、2*0.75~61*0.75、2*1.0~61*1.0、2*1.5~48*1.5、2*2.5~48*2.5

Crosslinked polyethylene insulated (or flame retardant, or halogen-free low-smoke flame retardant) control cables with a rated voltage of 450 / 750V and below

GB/T19666-2005

GB/T9330.2-2008

(Z*-)K YJ V 、(Z*-)K YJ VP 、WDZ*-KYJY、WDZ*-KYJYP

450/750V

2*0.75~61*0.75、2*1.0~61*1.0、2*1.5~61*1.5、2*2.5~61*2.5、2*4~14*4、2*6~14*6、2*10~10*10

(Z*-)K YJ VP2、(Z*-)K YJ VP 3、WDZ*-KYJYP2、WDZ*-KYJYP3

4*0.75~61*0.75、4*1.0~61*1.0、4*1.5~61*1.5、4*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10

(Z*-)K YJ V32、WDZ*-KYJY33

19*0.75~61*0.75、19*1.0~61*1.0、7*1.5~61*1.5、7*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10

(Z*-)K YJ V22、WDZ*-KYJY23

(Z*-)K YJ VP 2-22、WDZ*-KYJYP2-23

(Z*-)KYJVP22、WDZ*-KYJYP23

7*0.75~61*0.75、7*1.0~61*1.0、7*1.5~61*1.5、4*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10

Rated voltage 0.6 / 1kV xLPE insulated flame retardant refractory control cable

manufacturer's standard

(Z *(N))-K YJ V 、(Z *(N))-K YJ VP 、(WDZ*(N))-KYJY、(WDZ*(N))-KYJYP

0.6/1k V

2*0.75~61*0.75、2*1.0~61*1.0、2*1.5~61*1.5、2*2.5~61*2.5、2*4~14*4、2*6~14*6、2*10~10*10

(Z *(N))-K YJ VP2、(Z *(N))-K YJV P 3、(WD Z *(N))-K YJY P2、(WD Z *(N))-K YJY P 3

4*0.75~61*0.75、4*1.0~61*1.0、4*1.5~61*1.5、4*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10

(Z *(N))-K YJ V22、(WD Z *(N))-K YJY 23、(Z *(N))-K YJ VP22、(WD Z *(N))-K YJY P23、(Z *(N) )-K YJ VP2-22、(WD Z *(N) )-K YJY P2-23

7*0.75~61*0.75、7*1.0~61*1.0、7*1.5~61*1.5、4*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10


(Z *(N))-K YJ V32、(WD Z *(N))-K YJY 33

19*0.75~61*0.75、19*1.0~61*1.0、7*1.5~61*1.5、7*2.5~61*2.5、4*4~14*4、4*6~14*6、4*10~10*10


(Z *(N)) -K YJ VR 、(WD Z *(N)) -K YJY R

4*0.5~61*0.5、4*0.75~61*0.75、4*1.0~61*1.0、4*1.5~61*1.5、4*2.5~61*2.5


(Z *(N)) -K YJ VRP 、(WD Z *(N)) -K YJY RP

4*0.5~61*0.5、4*0.75~61*0.75、4*1.0~61*1.0、4*1.5~48*1.5、4*2.5~48*2.5